2016 Reichert 7CR Auto NCT Tonometer + Accessories+ User Manual- Touch Screen

$ 3432

Availability: 100 in stock
  • Country/Region of Manufacture: United States
  • UPC: Does not apply
  • Model: Reichert 7CR Auto NCT
  • Condition: Excellent condition-comes complete with all accessories and user manual. This tonometer looks, and functions like a brand new one. It is the latest and the most advanced NCT from from Reichert that is FULLY AUTOMATED. It incorporates the corneal response technology to give you Corneal Compensated IOP (IOPcc), a better indicator of glaucoma than other methods of tonometry, including Goldmann Applanation.See below for more details or visit Reichert's website.
  • MPN: 7CR Auto NCT
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Intended Use/Discipline: Optometry
  • Item must be returned within: 30 Days
  • Restocking Fee: No
  • Product: Tonometer
  • Brand: Reichert
  • Return shipping will be paid by: Buyer

    Description

    “The Glauco
    ma Tonometer”
    The Reichert 7CR from Reichert Technologies utilizes a patented bi-directional applanation process to characterize the biomechanical properties of the cornea and reduce their impact on the IOP measurement. This measurement, referred to as Corneal Compensated IOP (IOPcc) is minimally affected by corneal visco-elastic properties, thickness, or surgical procedures such as LASIK or PRK. As such, IOPcc is a better indicator of glaucoma than other methods of tonometry, including Goldmann Applanation.
    The Reichert 7CR is more clinically valid in all subjects, including:
    -Normal Tension Glaucoma patients
    -Primary Open Angle Glaucoma patients
    -Post-LASIK and refractive surgery patients
    -Patients with Fuchs’ or Corneal Edema
    -Keratoconus patients
    -Patients with thick, thin, or otherwise biomechanically atypical corneas
    Waveform Score ensures reliability of results:
    The Reichert 7CR employs an advanced signal-scoring feature that helps ensure the accuracy and reliability of measurement results. Each measurement is assigned a score based on internally-processed signal analysis algorithm. Scores below a certain threshold are indicated as unreliable. When multiple measurements are taken on the same eye, an intelligent averaging technique provides a weighted average, dependent upon the waveform score. No other tonometer provides operators with objective feedback about the quality of the measurement taken!
    Non-Contact measurement methodology:
    Alignment and measurement with the Reichert 7CR are FULLY AUTOMATED. A collimated air-jet provides gentle force to the cornea while an electro-optical system monitors the applanation process. The result is a rapid measurement that is comfortable and non-intimidating for the patient and simple for any operator to execute. Best of all, the measurement is non-contact so no anesthesia is required and there is no risk of cross contamination.
    Automatic, real-time applanation control:
    The Reichert 7CR applanation detection system monitors the change in corneal curvature in real time, recording 400 data samples during the 25 millisecond measurement process! This unique feature ensures that the appropriate applanation force is automatically delivered to each eye being measured.
    User and patient friendly:
    The all-new touch screen interface features an easy-to-use icon-based operating system enabling even inexperienced users to make measurements in seconds. The full color display guides the operator through the measurement process showing everything from the alignment of the eye, to the display of the readings.
    Patients simply lean against the forehead rest while the fully automated alignment and measurement takes place.
    Reichert 7CR has these great features:
    Easy-to-use, touch screen interface
    Patients simply lean against the forehead rest
    Alignment is completely automated
    One-touch, triple measurement mode
    Clearly displays all measurement data
    Internal printer simplifies record keeping
    Electronic data transfer via USB port